Vantage Property Inspections LLC
Photo Gallery
tn_00100P1010020_wm.JPG
Worn asphalt shingles on one side
tn_00200P1010022b_wm.JPG
Partial re-roof
tn_00300P1010043b_wm.JPG
Asphalt shingles at end of service life
tn_00400P1010022c_wm.JPG
Multiple layers with tar patching
tn_00500P1010036_wm.JPG
Multiple layer visible at edge
tn_00600P1010037b_wm.JPG
Low pitch roof with tar to repair leaks
tn_00700P1010025_wm_c.JPG
Typical brick chimney and flashing
tn_00800P1010026_wm.JPG
Water damage and spalled brick
tn_00900P1010031b_wm.JPG
Missing cap, crown and extensive water damage
tn_01000P1010038_wm.JPG
Attempt to repair roof/ flashing leaks using tar
tn_01100P1010034_wm.JPG
Water damage to ceiling below
tn_01200P1010036_wm.JPG
Old chimney with no flue lining
tn_01300P1010016_wm.JPG
Wood siding in direct contact with earth
tn_01400P1010010_wm.JPG
Damage to wood in conact with earth
tn_01500P1010030b_wm.JPG
Typical damage to garage door trim
tn_01600P1010043_wm.JPG
Foundation plantings too close to siding
tn_01700P1010019_wm.JPG
Poor adhesion of paint to wood siding
tn_01800P1010006_wm.JPG
Poor drainage and damage to retaining wall
tn_01900P1010012c_wm.JPG
Inadequately attached deck joists
tn_02000P1010040_wm.JPG
Unsafe stairs/ stringers
tn_02100P1010084b_wm.JPG
No bolts visible in ledger, improper joist hanger installation
tn_02200P1010060_wm_c.JPG
Well head close to ground - vulnerable to contamination
tn_02300P1010034b_wm.JPG
Loose fitting well cap allows entry of spiders, dirt, etc.
tn_02400P1010048c_wm.JPG
Older well located in basement
tn_02500P1010018b_wm.JPG
Tilting in garage foundation wall
tn_02600P1010018b_wm.JPG.JPG
Large crack in foundation wall
tn_02700P1010105_wm.JPG
Repair/ modification to foundation/ girder pocket
tn_02800P1010050b_wm.JPG
Damage/ rot at main beam end
tn_02900P1010083_wm.JPG
Subfloor/ joist damage from leaking toilet and excessive notching
tn_03000P1010084c_wm.JPG
Joist damaged by excessive notching in joist for piping
tn_03100P1010017_wm.JPG
Subterranean termite mud shelter tube on outside foundation wall
tn_03200P1010033_wm.JPG
Termite entry through gaps in foundation around pipe
tn_03300P1010029_wm.JPG
Mud shelter tube visible on inside of block foundation wall
tn_03400P1010039_wm.JPG
Termite "drop tubes" visible on joists
tn_03500P1010022d_wm.JPG
Mud shelter tubes and damage on floor joists
tn_03600P1010024_wm.JPG
Termite damage to floor joists
tn_03700P1010049b_wm.JPG
Damage to beam by powder post beetles
tn_03800P1010011_wm.JPG
Woodpecker damage due to foraging for carpenter bee larve
tn_03900P1010064_wm.JPG
Close up of holes from woodpeckers/ carpenter bees
tn_04000P1010084_wm.JPG
Effloresence from moisture or water penetration on block wall
tn_04100P1010035b__wm.JPG
Water penetration through wall under window well
tn_04200P1010012_wm.JPG
Water seepage through pipe penetration in basement wall
tn_04400P1010033b_wm.JPG
Fill and vent pipes connected to a buried fuel oil tank
tn_04500P1010086_wm.JPG
Disconnected buried oil tank lines visible at basement wall
tn_04600P1010046_wm.JPG
Oil lines previously used to supply oil from a buried oil tank
tn_04700P1010045b_wm.JPG
New copper main water supply line
tn_04800P1010037_wm.JPG
Older galvanized steel main water line
tn_04900P1010054_wm.JPG
Lead main water supply line
tn_05000P1010072b_wm.JPG
Threaded brass water line
tn_05100P1010074_leak_wm.JPG
Leaking shower drain visible from crawl space
tn_05200P1010135_wm.JPG
Typical corroded P-trap visible under sink
tn_05201asbestos02.JPG
Asbestos type insulation visible on heating pipes in basement
tn_05202P1010032_wm.JPG
Portions of asbestos insulation remain after incomplete removal
tn_05203P1010031_wm.JPG
New fiberglass insulation, possible asbestos remnants on pipe
tn_05300P1010035b_wm.JPG
Furnaces with rusted sheet metal from leaking humidifiers
tn_05400P1010057.JPG
Very old "snowman" boiler
tn_05500P1010035_wtr_htr_wm.JPG
Gas water heater with disconnected smoke pipe
tn_05600P1010010c_wm.JPG
Loose electrical meter panel
tn_05700P1010018_wm.JPG
Rusted out bottom of electrical service panel
tn_05800P1010050_wm.JPG
Grounding electrode conductor disconnected from ground rod
tn_05900P1010023_wm.JPG
AC disconnect missing terminal cover plate
tn_06000P1010048_wm.JPG
Federal Pacific brand electric panel - poor reliability record
tn_06100P1010014_wm.JPG
Old style edison fuse panel - overfused with 30 amp fuses
tn_06200P1010070_wm.JPG
Garage roof leak resulted in extensive corrosion at CB terminals
tn_06300P1010125_wm.JPG
Corrosion at a neutral bus bar
tn_06400P1010088_wm.JPG
Loose receptacle - junction box extender missing
tn_06500P1010030_wm.JPG
Evidence of water entry behind drywall in subgrade room
tn_06600P1010077_wm.JPG
Crowning in newly installed wood floor
tn_06700P1010012b_wm.JPG
Condensation indicates deficient seal
tn_06800P1010013_wm.JPG
Excessive moisture/ inadequate ventilation in attic
tn_06900P1010045_wm.JPG
Damage to roof sheathing caused by roof/ flashing leak
tn_07000P1010073_wm.JPG
Inadequate attic insulation
tn_07100P1010001_wm.JPG
Incomplete installation of AC air handler condensation drain
tn_07200P1010049_wm.JPG
Disconnected dryer vent exhausts lint, moisture into attic
tn_07300P1010051_wm.JPG
Bathroom fan exhaust duct damaged, adding moisture to attic
  